MIL-DTL-62069G(AT)
Figure 2. Limit for UMO5 conducted emissions.
3.6.1.2 Flasher unit. The flasher unit shall operate in a temperature of 160 ±5F without
malfunction. The flasher unit shall meet the requirements of 3.4.4 throughout the test (see
4.4.5.1.2).
3.6.2 Low temperature.
3.6.2.1 Control unit. The control unit shall operate in a temperature of -65 ±5F
without malfunction. The control unit shall meet the requirements of 3.5.1 throughout the test
(see 4.4.5.2.1).
3.6.2.2 Flasher unit. The flasher unit shall operate in a temperature of -65 ±5F without
malfunction. The flasher unit shall meet the requirements of 3.4.4 throughout the test (see
4.4.5.2.2).
3.6.3 Shock. The control and flasher units shall evidence no loosened, distorted, or
broken parts. The signal control lever shall not be displaced during the test (see 4.4.5.3).
Subsequently, the control unit shall meet the requirements of 3.5.1 and the flasher unit shall meet
the requirements of 3.4.4.