MIL-DTL-62069G(AT)
TABLE III. Order of first article testing for flasher unit.
Specimen
Paragraph No.
Tests
4.4.3.1
Flashing
1
4.4.5.2.2
Low temperature
4.4.3.1
Flashing
4.4.5.1.2
High temperature
4.4.3.1
Flashing
4.4.3.4
Endurance
4.4.3.1
Flashing
4.4.3.1
Flashing
2
4.4.3.5
Transient capability
4.4.3.1
Flashing
4.4.3.2.2
Overload
4.4.3.1
Flashing
4.4.3.3
Reverse polarity
4.4.3.1
Flashing
4.4.5.4
Vibration
4.4.3.1
Flashing
4.4.5.5
Waterproofness
4.4.3.2.2
Overload
4.4.3.1
Flashing
4.4.3.1
Flashing
3
4.4.5.3
Shock
4.4.3.1
Flashing
4.4.5.6
Corrosion resistance
4.4.3.1
Flashing
4.4.3.2.2
Overload
4.4.3.1
Flashing
Electromagnetic
4
4.4.3.6
interference
4.3.2 Examination. Samples selected in accordance with 4.3.1 shall be examined for
defects such as incorrect dimensions affecting interchangeability, incorrect luminescent area,
improper finish, improper marking, and faulty workmanship. Examination shall be visual,
tactile, or by measurement with standard inspection equipment (SIE).
4.3.3 Conformance tests for flasher. Samples selected in accordance with 4.3.1.3 shall be
subjected to the tests specified in table IV.
12
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.