3.5.4 Fungus. Materials which are nonnutrients shall be used where possible. Fungus
growth shall not cause performance degradation (see 4.5.4.4).
3.5.5 Shock (nonoperating). The motor shall not show evidence of physical damage or
degradation of performance impaired after exposure to shock waves when exposed to tests of
4.5.4.5.
3.5.6 Vibration (nonoperating). The motor shall not be damaged nor its performance
impaired after being exposed to vibration in 4.5.4.6.
3.5.7 Proof pressure. The motor shall not be damaged nor its performance impaired
after being exposed to a proof pressure in accordance with 4.5.4.7.
3.5.8 Burst pressure. The motor shall not be damaged nor its performance impaired
after being exposed to a burst pressure in accordance with 4.5.4.8.
3.6 Identification marking plates. Motor assemblies shall be identified as specified in
Drawing 12265504. Identification markings, shall meet the requirements of ANSI/AS478 and
shall include the following information as a minimum (see 4.5.1):
a.
Motor hydraulic: type I, class 3000
b.
Constant displacement: 0.12 cu in per revolution
c.
Manufacturer's name and FSCM number
d.
Fluid: MIL-PRF-6083
e.
Serial number
f.
Military part number: 12265504
g.
Federal stock number
h.
Manufacturer's part number
i.
Date of manufacture
j.
Contract number (month/year)
k.
Cage code: 19207.
3.7 Workmanship. All parts shall be fabricated and assembled in a thorough and
workmanship like manner. They shall be free of burns. chips, sharp edges, cracks, unblended
radii, surface defects, dirt, grease, corrosion, process residue and other foreign matter. Exposed
surfaces shall not have chipped, scratched, peeling, or incorrect finishes. The unit shall contain no
rust or corrosion. Screw threads shall be clean and to the full depth required (see 4.5.1).
8
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business